Description
The Caloritech 50kW 600V GX Forced Air Unit Heater w/T’stat (GX508CT) is an industrial-grade electric heater specifically designed for robust and continuous operation in the most demanding commercial and industrial settings. Part of the GX Heavy Duty Series, this unit is engineered to deliver reliable forced air heating while minimizing maintenance and maximizing operational uptime in environments where standard heaters often fail. Its comprehensive feature set, combined with heavy-duty construction, makes it an essential heating solution for critical infrastructure and demanding workspaces.
KEY FEATURES AND BENEFITS:
- Engineered for Heavy Duty Industrial Use: Specifically built to withstand and perform in harsh environments such as mine shafts, pulp and paper mills, hoist houses, welding shops, maintenance areas, sewage treatment facilities, chemical plants, weigh scale pits, elevator shafts, and crane cabs.
- Reduced Downtime and Maintenance: The robust construction and thoughtful design of this heater are intended to significantly lower the frequency of repairs and servicing, ensuring sustained operation in critical applications.
- Efficient Forced Air Heating: Delivers 50,000 W (50 kW) of heating power, providing 170,600 Btu/hour of consistent warmth through powerful forced air circulation to quickly heat large spaces.
- Integrated Thermostat: Features a built-in thermostat for convenient temperature control, typically allowing settings between 41°F and 100°F (5°C and 38°C), ensuring optimal comfort and energy management.
- Comprehensive Safety Controls: Equipped with multiple safety features including an automatic reset high-limit, manual reset high limit, a disconnect switch with door interlock, HRC main load fuses, and a fused control circuit to ensure safe and reliable operation.
- Durable Cabinet Design: Constructed with 14-gauge steel and finished with an epoxy paint (ASA61 Grey) for enhanced corrosion resistance, extending the life of the unit in challenging conditions.
- Optimized Motor and Heating Elements: Features a 1/3 HP motor with sealed ball bearings mounted outside the element bundle to prevent overheating and simplify maintenance. Heating elements are robust Caloritech™ type KX finned tubular sheathed with epoxy-sealed terminals to prevent contamination.
- Energy Management Compatibility: The 50 kW capacity includes split loads (50%) to facilitate integration with remote energy management systems, allowing for more efficient power consumption.
- Flexible Airflow and Mounting: Offers individually adjustable louvres for precise airflow direction and includes a ceiling mounting bracket for versatile installation options.
SPECIFICATIONS:
- Wattage: 50,000 W (50 kW)
- Voltage: 600 V
- Phase: 3Ø
- Amps: 49.2 Amps
- Heat Output: 170,600 Btu/hour
- Assembled Dimensions (L x W x H): 31 in. x 23 in. x 18.5 in.
- Ship Weight: 130.0 lbs
- Product Weight: 125.0 lbs
- Blower CFM: 2,200 cfm
- Motor: 1/3 HP
- Thermostat Temperature Range: 41°F to 100°F (5°C to 38°C)
- Warranty: 1-year limited warranty
HOW TO USE:
- Mounting: Securely attach the unit heater using the provided ceiling mounting bracket in the desired location. Ensure the mounting surface can support the unit’s weight.
- Electrical Connection: Have a qualified electrician hardwire the unit to a dedicated 600V, 3-phase electrical circuit. Verify all connections are secure and comply with local electrical codes.
- Power On: Once installation is complete and verified, switch on the main power supply to the unit. The disconnect switch on the heater’s control panel should be engaged.
- Set Temperature: Adjust the built-in thermostat to your desired temperature setting. The fan will typically activate after a brief delay to ensure the heating elements are adequately warmed.
- Adjust Airflow: Utilize the individually adjustable louvres on the front of the unit to direct the heated air towards the specific areas requiring warmth.
- Operation Monitoring: The unit will operate automatically to maintain the set temperature. Periodically check the unit for proper functioning and clear any obstructions from the air intake and output.
- Shutdown (if needed): To turn off the heater, set the thermostat to its lowest setting or use the integrated disconnect switch on the control panel, followed by turning off the main circuit breaker.
BENEFITS OF USING CALORITECH 50KW 600V GX FORCED AIR UNIT HEATER W/T’STAT (GX508CT):
- Reliable Operation in Harsh Settings: Specifically built to maintain performance and extend service life in extreme industrial conditions, where standard heaters might fail prematurely.
- Minimized Operational Interruptions: Its heavy-duty construction translates directly into fewer breakdowns and maintenance needs, ensuring continuous heating when it’s most critical.
- Precise Climate Control: The integrated thermostat allows for accurate temperature management, contributing to energy efficiency and a more comfortable working environment.
- Enhanced Safety: Equipped with multiple layers of safety mechanisms, including high-limit cut-offs and a door interlock, providing peace of mind during operation.
- Long-Term Value: The robust materials and design contribute to a longer operational lifespan, representing a cost-effective heating investment over time in challenging applications.
- Adaptable Air Distribution: Adjustable louvres provide the ability to direct heated air efficiently, optimizing heat distribution for different layouts and specific warming requirements.
- Streamlined Integration: Designed with features like split loads for energy management systems and clear mounting instructions, simplifying its incorporation into existing industrial setups.
FEATURES:
- Hardwired installation requirement.
- Designed for indoor use in non-hazardous industrial and commercial environments.
- CSA approved for both horizontal and vertical airflow configurations.
- Manual reset high limit for enhanced safety control.
- Automatic reset high limit for continuous operation safety.
- HRC main load fuses for circuit protection.
- Fused control circuit for sensitive component protection.
- Full-sized control panel with a hinged, removable door.
- Control panel constructed to EEMAC 12 standards.
- 1/3 HP motor with sealed ball bearings.
- Totally enclosed motor construction.
- Motor positioned outside the element bundle to prevent premature failure.
- Caloritech™ type KX finned tubular sheathed heating elements.
- Epoxy sealed terminals on heating elements to prevent contamination.
- Low voltage relay for 24V remote thermostat connections.
- Fan delay feature for both ON and OFF cycles.
- Cabinet finished with ASA61 Grey epoxy paint.